Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13776413
- Product Categories
- Friendly Links
- home > Supply > Gas chromatography, gas chromatography import monopoly, Chun Di instruments (quality businessmen)
Information Name: | Gas chromatography, gas chromatography import monopoly, Chun Di instruments (quality businessmen) |
Published: | 2015-06-29 |
Validity: | 0 |
Specifications: | Any |
Quantity: | |
Price Description: | |
Detailed Product Description: | GC Smart as a good product by gas chromatography, has the following characteristics: 1. Excellent Performance (1) digital pressure / flow display GC Smart host standard AFM (advanced traffic monitoring) and APM (advanced pressure monitor), so that the operator simply adjust the air passage knob, Agilent gas chromatographs, you can easily get the current carrier gas, hydrogen and air flow rate / pressure parameters from the host large LCD display, imported gas chromatograph monopoly, without flow meter, without having to manually calculate the split ratio. Eliminating the tedious exploration and analysis conditions setting process, to the operator to bring an unprecedented experience. (2) Flexible system expansion to meet the requirements of various fields GCSmart supports single / dual packed column inlet, split / splitless capillary column injector, any single / double FID detector, TCD detector and other units match. It can simultaneously load two inlets and two detectors. After a host can easily purchase additional inlets, detectors and other units. (3) easy to upgrade to the autosampler, GC, GC Smart achieve high throughput analysis has autosampler AOC-20i power supply built into the host. Users only need to purchase injection tower means you can instantly upgrade to the autosampler, to facilitate high-throughput analysis. While supporting a variety of auxiliary injection capabilities, such as headspace, purge and trap, thermal desorption, pyrolysis, etc. Shimadzu GC Smart3. Operation and maintenance is simple (1) using a large LCD display can accommodate large part of the large amount of information displays and graphical man-machine dialogue, setting the analysis conditions in a short time. (2) simple LED warning lights on the control panel, streamlined design of the LED warning lights use different colors and strobe, played well overall Prompts. It uses all too familiar with exactly the same color of traffic lights to serve as a warning, letting arc design tedious testing work a little more playful. In addition, operating tips and all of the text on the keyboard using the character prompt, so users will not ignore or miss a control every detail. Gas Chromatograph GC-2010 Plus main features: First, the increasing 2010Plus for trace analysis of high sensitivity detector series with the constant strict, high-sensitivity analysis of trace amounts of various laws and regulations requirements. To meet this demand, Shimadzu FPD, FID detector, etc. carried out a thorough re-design and processing, so as to achieve the world's leading sensitivity level, more suitable for trace analysis. Second, improve the efficiency of the analysis of the many functional column oven rapid cooling, cleaning technology, gas saver function. 1, column oven rapid cooling increases the separate cooling fan, and optimized air circulation, making the oven cool down rate significantly increased (from 450 ° C down to 50 ° C requires only 3.4 minutes). Fan noise is minimized. When using the cleaning function, the analysis time will be further reduced. 2, Advanced Flow Technology AFT (AdvancedFlow Technology) series of new flow path control technology to meet the high-throughput, high-efficiency analysis. Cleaning system to shorten the analysis time when the target compound is detected, the cleaning system by changing the carrier gas to purge out the remaining residual material from the inlet side of the bypass flow path, gas chromatography retail, shorten analysis time and improve the efficiency of the analysis. Detector shunt system to improve the accuracy and efficiency of the analysis of qualitative shunt detector system will analyze the material after the separation column diverted to different detectors, access to a variety of spectral information to get accurate qualitative information. 3, rich in self-test function prevent equipment failure to use self-test function, checking device is functioning. Temperature sensor can be examined in detail, controlled conditions, gas pressure, prevent unexpected equipment downtime. Gas chromatography, gas chromatography import monopoly, Chun Di instruments (quality businessmen) from Hunan Chun Di Equipment Co., Ltd.. Road Zhiyuan, temper forward. Hunan Chun Di Equipment Co., Ltd. (www.hnjdyq.com/) aims to become and you win symbiosis, strategic partners to move forward, more determined to become the most influential analytical instruments business, and you leap together to success ! |
Admin>>>
You are the 17075 visitor
Copyright © GuangDong ICP No. 10089450, Hunan Chun Di Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 17075 visitor
Copyright © GuangDong ICP No. 10089450, Hunan Chun Di Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility